Skip to main content

Table 4 Mean error step scores and limits of agreement during 24 hour observation period

From: Accuracy of uploadable pedometers in laboratory, overground, and free-living conditions in young and older adults

Pedometer 20-49 yrs (n=10) 50-80 yrs (n=10)
OM 949.1* (597.8, 1300.4) 612.9* (34.4, 1191.4)
LC −305.1 (−709.9, 99.7) −38.0 (−936.6, 860.6)
  1. Note. OM = Omron HJ-720ITC, LC= Kenz Lifecorder EX;* significantly different than zero p<0.025.